[China Instrument Network Standards Sharing Circle] A few days ago, the National Standards Committee issued the third batch of national standards project to be approved in 2015, a total of 930 items. According to the statistics of Xiao Bian, a total of 43 national standards related to instrumentation will be revised, and most of the standards fall under the “Made in China 2025” requirement. For details of the standard, please see the page.

No.
standard name
For details, please see
1
Resistance thermometer with platinum wire
page 1
2
Cryogenic valve Technical conditions
page 1
3
Power station temperature reducing and pressure reducing valve
page 1
4
Natural gas metering system performance evaluation method
page 1
5
Ultrasonic flowmeters measure liquid hydrocarbon flow
page 1
6
Industrial Communication Network Profiles Part 3: Functional Safety Fieldbus General Rules and Regulations
page 2
7
Gas flow meter volume corrector
page 2
8
Ultrasonic gas meter
page 2
9
Transmitters for industrial process control systems. Part 3: Assessment methods for smart transmitters
page 2
10
Field Device Tool (FDT) Interface Specification Part 1: Overview and Guidelines
Page 3
11
Field Device Tool (FDT) Interface Specification Part 2: Concepts and Detailed Description
Page 3
12
Field Device Tool (FDT) Interface Specification Part 42: Object Model Profile Integration General Voice Basics
Page 3
13
Industrial process temperature calibrator
Page 3
14
Test method for air enthalpy test, general technical requirements
Page 3
15
Drinking cold Water Meters and hot water meters Part 1: Metering and technical requirements
Page 4
16
Drinking Cold Water Meters and Hot Water Meters Part 2: Test Methods
Page 4
17
Drinking Cold Water Meter and hot water meter Part 3: Test report format
Page 4
18
Drinking cold water meter and hot water meter Part 4: Non-metering requirements not included in GB/T 778.1
Page 4
19
Drinking Cold Water and Hot Water Meters Part 5: Installation Requirements
Page 4
20
Industrial Process Control Valves Part 8-2: Noise Considerations Measurement of Noise from a Hydrodynamic Flow through a Control Valve in a Laboratory
Page 5
twenty one
Diaphragm gas meter
Page 5
twenty two
Thermocouples Part 1: Specifications and tolerances for electromotive force
Page 5
twenty three
All-welded ball valve installation and maintenance methods
Page 5
twenty four
Industrial Control Embedded Systems Information Security Part 1: General
Page 5
25
Industrial Control System Anomaly Monitoring Tools Technical Requirements and Test Evaluation Methods
Page 5
26
Industrial Communication Networks - Network and System Information Security Part 3-3: System Information Security Requirements and Information Security Levels
Page 6
27
Technical Requirements for Information Security of Urban Rail Transit Control System
Page 6
28
Valve Positioners for Industrial Process Control Systems Part 2: Performance Evaluation Method for Pneumatic Output Smart Valve Positioners
Page 6
29
Industrial Control Computer Information Security Part 1: Guidelines for Evaluation
Page 6
30
Field Device Tool (FDT) Interface Specification Part 62: Field Device Tool (FDT) style guide based on Common Language Architecture
Page 7
31
Field Device Tool (FDT) Interface Specification Part 52-10: General Language Based Communication Implementation IEC 61784 CPF 1
Page 7
32
Field device tool (FDT) interface specification 52 - 20: Communication common language infrastructure to achieve --IEC 61784 CPF 2
Page 7
33
Field Device Tool (FDT) Interface Specification Part 52-31: Communication Implementation of Common Language Infrastructure - IEC61784 CP3/1 and CP3/2
Page 7
34
Field Device Tool (FDT) Interface Specification Part 52-32: General Language Infrastructure Communication Implementation IEC 61784 CP3/4, CP3/5 and CP3/6
Page 7
35
Field Device Tool (FDT) Interface Specification Part 52-90: General Language Infrastructure Communication Implementation IEC 61784 CPF 9
Page 7
36
Field Device Tool (FDT) Interface Specification Part 52-150: Communication Implementation of Common Language Infrastructure
Page 7
37
Industrial Process Measurement and Control Meter Reliability Allocation Guidelines
Page 8
38
Industrial firewall information security technical requirements
Page 8
39
Ozone calibration analyzer
Page 8
40
Automatic Determination of Water Content in Crude Oil and Liquid Petrochemical Products RF Method
Page 8
41
Water level measuring instruments Part 1: Float water level gauges
Page 9
42
Rotor type flow meter
Page 9
43
Information Technology Sensor Network Technical Requirements for Remote Gas Metering Applications
Page 9
standard name
Resistance thermometer with platinum wire
Standard nature
recommend
Standard status
Revision
Revised standard number
GB/T 5977-1999
ICS classification number
17.200.20
Project Cycle
24 months
Date of publication
2015-09-24
deadline
2015-10-15
Competent authority
China Machinery Industry Federation
Drafting unit
Chongqing Materials Research Institute Co., Ltd.
Reporting unit
National Instrument Functional Materials Standardization Technical Committee
Centralized units
National Instrument Functional Materials Standardization Technical Committee
Purpose meaning
The platinum resistance thermometer is one of the most important commonly used temperature measuring instruments at home and abroad, and it is also a standard instrument that is commonly used in the world as a temperature scale of 13.8333K~961.78°C. It has played an important role in ensuring the consistency and accuracy of international temperature values. Pure platinum wire is currently the most important resistance thermometer material. Due to its high melting point, it has good chemical stability and excellent oxidation resistance at high temperatures. Its high resistivity, good plasticity, and easy access to high-purity filaments have long been used to make platinum resistance thermometers. According to the use conditions and technical requirements, thermometers are often divided into standard platinum resistance thermometers and industrial platinum resistance thermometers. The standard platinum resistance thermometer is mainly used in the laboratory to transfer the international practical temperature scale (ITS-90) and precision temperature measurement; the industrial platinum resistance thermometer is mainly used to produce the temperature measured from -200°C~850°C. The structure of the two resistance elements is different, and the platinum wire used is different. The standard platinum resistance thermometer is the most precise and stable thermometer. Due to the presence of impurities and the presence of defects in any trace amount, the performance and instability of the platinum can be caused. The platinum wire used for the production of standard platinum resistance thermometers must be of the highest purity and not only chemical properties, but also the physical properties, temperature coefficient of resistance, and resistance ratio should be strictly stipulated. In 1986, China issued two national standards, namely the platinum wire for GB 5977-86 resistance thermometers and the platinum wire resistance ratio test method for GB 5978-86 resistance thermometers. In 1999, it was revised to GB/T 5977-1999 "Platinum wire for resistance thermometers". This standard has played an important role in the transmission of temperature standards in China and the development of industrial temperature measurement technology. Since the implementation of this standard, it has been 15 years since then. With the continuous development of China's industrial industry, the application range of platinum wire for resistance thermometers has been continuously expanding and the technical performance has been continuously improved. In order to meet the needs of the development of science and technology in China, it is urgent to revisit the national standard.
Domestic and foreign situation
In order to ensure the accuracy of the international temperature scale, and reproduce the same temperature scale with high accuracy to ensure the unity and accuracy of international temperature values, our institute completed the ITPS-68 temperature scale instrument as early as the 1980s. Standardization work has led to the formulation of national standards. The implementation of this standard has played a considerable role in the transmission of temperature standards in China and the development of industrial temperature measurement technology for many years. According to the resolutions of the 18th International Conference on Metrology (CGPM) and the 77th International Metrological Committee (CIPM), the "International Temperature Scale of 1990 (ITS-90)" was implemented worldwide as of January 1, 1990. “International Practical Temperature Scale (IPTS-68) in 1968” and “Temperature Temperature Scale of 0.5-30K (EPT-76) in 1976”. In the ITS-90 international temperature standard, the definition of the standard thermometer resistance ratio W has changed, and the control value of the thermometer resistance ratio has also changed. IEC 60751 "Industrial Platinum Resistance Thermometers and Platinum Temperature Sensors" was developed in 1983 and revised in 1986, 1995 and 2008 respectively. The national standard “Platinum Wire for Resistance Thermometers”, which is the key material for its support, should be revised as soon as possible to achieve convergence and harmonization with international standards.
Note
According to the national review of the national standards of the National Instruments Functional Materials Standardization Technical Committee (SAC/TC419) 2014, the revised plan for the national standard was proposed in 2014. The plan was approved by the Standards Committee at its annual meeting in 2014. Belongs to Work Point 12 "New Materials"
standard name
Cryogenic valve Technical conditions
Standard nature
recommend
Standard status
Revision
Revised standard number
GB/T 24925-2010
ICS classification number
23.060.01
Project Cycle
36 months
Adopt international standards
ISO-28921-1-2013
Date of publication
2015-09-24
deadline
2015-10-15
Competent authority
China Machinery Industry Federation
Drafting unit
Shanghai Lianggong Valve Factory Co., Ltd., Shanghai Nafushi Valve Co., Ltd., Hefei General Machinery Research Institute, Baoyi Group Co., Ltd., etc.
Reporting unit
National Valve Standardization Technical Committee
Centralized units
National Valve Standardization Technical Committee
Purpose meaning
GB/T24925 has been released since 2009 and has been for 5 years. The formulation of the standard is based on the original machinery industry standard JB/T7749-1995 "Technical conditions of cryogenic valves", based on the principle of inheritance of standards, the continuation of some terms. At that time, the international standards for cryogenic valves had not yet been introduced. This standard was limited by the prevailing conditions. The content of the test requirements and other aspects formulated were incompatible with the domestic production reality and the international standards that were issued in 2013, especially at present. The rapid development of low temperature engineering technology. The quality of cryogenic valves determines whether low temperature engineering can be safely, economically, and continuously produced, and determines the process of localization of cryogenic valves. Therefore, it is necessary to revise the product standard GB/T24925-2010 for cryogenic valves. In order to facilitate the international practice, effectively guide the design, manufacture, testing and acceptance of cryogenic valve products.
Scope and main
Technical content
This standard was limited by the prevailing conditions. The content of the test requirements and other aspects formulated did not meet the domestic production reality and the international standards issued in 2013, especially with the rapid development of low-temperature engineering technology. The quality of cryogenic valves determines whether low temperature engineering can be safely, economically, and continuously produced, and determines the process of localization of cryogenic valves. Therefore, it is necessary to revise the product standard GB/T24925-2010 for cryogenic valves. In order to facilitate the international practice, effectively guide the design, manufacture, testing and acceptance of cryogenic valve products.
Domestic and foreign situation
After retrieval, the relevant foreign standards are as follows: 1, BS6364: 1989 "Cryogenic Valve" Only the British system size. Due to many years of unrevised, many of the provisions are not suitable for the needs of the development of low-temperature industries. 2. MSS SP-134-2006 “Requirements for cryogenic valves and their body/bonnet extensions” is mainly aimed at the extended part of cryogenic valves and is not a product standard. 3, DIN EN1626-1999 "Cryogenic vessel valve for cryogenic vessels" has a narrow range of applications. 4, MESC SPE 77/200-2008 "Cryogenic and cryogenic valves" are available in inch sizes only. It is not widely used on a global scale and few domestic companies have adopted it. 5. ISO-28921-1-2013 Industrial Valves—Cryogenic Isolation Valves Part 1 Design, manufacturing, and product testing are the new standards issued by the ISO International Organization for Standardization in 2013. The range covers imperial, metric cryogenic valves. 6, domestic GB/T24925-2010 cryogenic valve technology conditions
Note
The standard project was discussed and approved by the standard committee and is a project on the valve standard system. Basic common
standard name
Power station temperature reducing and pressure reducing valve
Standard nature
recommend
Standard status
Revision
Revised standard number
GB/T 10868-2005
ICS classification number
23.060
Project Cycle
24 months
Date of publication
2015-09-24
deadline
2015-10-15
Competent authority
National Standardization Management Committee
Drafting unit
Hangzhou Huahui Valve Co., Ltd., Shanghai Power Equipment Design Institute
Reporting unit
National Boiler Pressure Vessel Standardization Technical Committee
Centralized units
National Boiler Pressure Vessel Standardization Technical Committee
Purpose meaning
The temperature reducing and pressure reducing valve of the power station is the main auxiliary equipment of the thermal power plant. It is an energy conversion device that reduces the high-parameter steam to the required steam parameters through the temperature reducing and pressure reducing valve. Power station temperature reducing valve is divided into two kinds of pressure reducing valve and pressure reducing valve. The steam conversion of general high-temperature and high-pressure steam is realized by using a pressure reducing valve and a steam desuperheating device, which can greatly improve the reliability of the equipment. The steam conversion of the steam under the high temperature and high pressure is realized by a temperature reducing and pressure reducing valve. The structure is compact, the floor space is small, the quality is light, and the layout is flexible and convenient. However, the structure of the temperature reducing and pressure reducing valve (pressure reducing valve) is complicated, and the manufacturing process requirements are high, and the GB/T10868-2005 "power station temperature reducing and pressure reducing valve" standard is relatively long-lived and it is urgent to modify its technical content. Further standardize design, manufacturing, and acceptance behaviors.
Scope and main
Technical content
Main contents: Ordering requirements, performance specifications, technical requirements, inspections and tests, performance tests, quality certificates, signs, packaging, storage, and transportation of power station temperature reducing and pressure reducing valves (power station pressure reducing valves). Range: Suitable for work pressure P ≤ 25.4MPa, operating temperature t ≤ 570 °C Parameter used under the conditions of power station steam system with power station temperature reducing valve (power station pressure reducing valve) (hereinafter referred to as valve).
Domestic and foreign situation
There is only this standard in China and there are no such standards in foreign countries.
Note
Stable growth points 20 special equipment
standard name
Natural gas metering system performance evaluation method
Standard nature
recommend
Standard status
Formulation
ICS classification number
75.180.30
Project Cycle
24 months
Date of publication
2015-09-24
deadline
2015-10-15
Competent authority
National Standardization Management Committee
Drafting unit
National Oil & Gas Large Flow Measurement Station Guangzhou Substation, National Oil & Gas Large Flow Measurement Station, Beijing Gas Co., Ltd.
Reporting unit
National Oil and Gas Standardization Technical Committee Oil and Gas Measurement and Analysis Methods Subcommittee
Centralized units
National Oil and Gas Standardization Technical Committee
Purpose meaning
Purpose: To provide scientific and standard methods for the performance evaluation of pre-production and in-service natural gas metering systems to meet the regulatory requirements for the rapid development of domestic natural gas trade handover measurement. Significance: To standardize the performance evaluation methods for natural gas metering systems to ensure that natural gas metering is fair, scientific, accurate, and reliable, which is of great economic and social significance.
Scope and main
Technical content
Scope: The method for evaluating the performance of natural gas metering systems is specified, and the calculation method for the measurement uncertainty of volumetric and energy related quantities under standard reference conditions in natural gas metering systems is given. Main technical contents: 1) Evaluation method of measuring equipment in natural gas metering system; 2) Calculation and evaluation method of uncertainty measurement of correlated quantity in natural gas metering system; 3) Comprehensive performance evaluation method of natural gas metering system.
Domestic and foreign situation
ISO 10723 Natural gas - Performance evaluation for analytical systems, and GB/T 28766-2012 “Performance Evaluation of Natural Gas On-Line Analytical Systems” established in accordance with ISO 10723:1995 are the evaluation standards for on-line chromatographs in natural gas metering systems. There is no evaluation standard for natural gas measurement systems in foreign countries, and it is necessary to specify that the evaluation methods are all reflected in the contract. There is no evaluation of natural gas measurement systems in China, and no standard is available.
Note
Steady growth. Strengthen energy development.
standard name
Ultrasonic flowmeters measure liquid hydrocarbon flow
Standard nature
recommend
Standard status
Formulation
ICS classification number
75.180.30
Project Cycle
12 months
Date of publication
2015-09-24
deadline
2015-10-15
Competent authority
National Standardization Management Committee
Drafting unit
PetroChina Institute of Metrology and Measurement, PetroChina Pipeline Company, Daqing Oilfield Co., Ltd.
Reporting unit
National Oil and Gas Standardization Technical Committee Oil and Gas Measurement and Analysis Methods Subcommittee
Centralized units
National Oil and Gas Standardization Technical Committee
Purpose meaning
Multichannel gas ultrasonic flowmeters have been widely used in natural gas flow measurement both at home and abroad. In recent years, foreign multi-channel liquid ultrasonic flowmeters have been developed for the transfer of liquid hydrocarbons such as crude oil and refined oil. From the perspective of application effects, multi-channel liquid ultrasonic flowmeters have outstanding advantages in large-diameter pipelines, which can reduce the overall cost of large-caliber pipeline flowmeters, and the construction of its non-movable parts and its improved self-diagnostic function have been greatly improved. The reliability of flow measurement, no additional pressure loss makes it have obvious advantages in terms of energy saving. The turndown ratio is much larger than other liquid flowmeters. It is a kind of volume flowmeter, turbine flowmeter, and mass flowmeter. Selected liquid hydrocarbons custody transfer meters. At present, there are no domestic standards and specifications for the application of ultrasonic flowmeters for the measurement of liquid hydrocarbons. There are foreign relevant standards in the field, and it is necessary to formulate industrial standards for liquid hydrocarbon measurement suitable for domestic use based on API MPMS 5.8.
Scope and main
Technical content
It is applicable to the selection, installation, operation and maintenance of time difference method ultrasonic flowmeter in the field of liquid hydrocarbon flow measurement. The main technical content includes: structure principle of the flow meter, selection principle, installation requirement, measurement method, as well as measurement system design requirements and technical conditions of safety, operation, performance, maintenance, and verification.
Domestic and foreign situation
Foreign manufacturers have used the successful experience of time difference method multi-channel gas ultrasonic flowmeters for the development of liquid ultrasonic flowmeters to produce time-difference multi-channel liquid ultrasonic flowmeters suitable for trade measurement of crude oil and refined oil, which were applied in 2005. In the crude oil, refined oil delivery measurement station, and achieved good results. In 2011, based on API MPMS 5.8 "Measurement of Liquid Hydrocarbons by Ultrasonic Flow Meters: 2005", the American Petroleum Institute revised and published the 2011 version of the standard. At present, there are neither ultrasonic flowmeters applied to the relevant standards in the field of liquid hydrocarbon measurement, nor are field precedents in which ultrasonic flowmeters are used in the measurement of liquid hydrocarbons.
Note
Steady growth. Natural gas import measurement standards.


Heat Meters are one kind of meters measuring the heat consumption. In order to save the energy and decrease the environment pollution, the heat meters are more and more popular for the modern buildings. Heat meters can realize centralized heating supply. Now with the rapid technology development, the heat meters also experience a fast way of growing up. Now the government of the world starts to pay much attention to the building remolding and new buildings heat meter installation. As the new type of energy calculation, the heat meters have the advantages of higher accuracy, energy saving and easy installation.

From the functions of the different types of heat meters, there are mechanical heat meters, Digital Heat Meter,Ultrasonic Heat Meters, M-bus Heat Meters and also wireless heat meters. Our company, Berggruen Technology Co.,Ltd never stops the steps for further higher technology research and development. We are devoted to study the new technology in the world to make better quality heat meters.



Heat Meters

Heat Meters,Mechanical Heat Meters,Ultrasonic Heat Meters,M-Bus Heat Meter,Digital Heat Meter

Berggruen Technology Co.,Ltd , http://www.meter-technology.com